Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 14(1): 6533, 2024 03 19.
Artigo em Inglês | MEDLINE | ID: mdl-38503773

RESUMO

Nitrogen (N) and phosphorus (P) are vital for crop growth. However, most agricultural systems have limited inherent ability to supply N and P to crops. Biochars (BCs) are strongly advocated in agrosystems and are known to improve the availability of N and P in crops through different chemical transformations. Herein, a soil-biochar incubation experiment was carried out to investigate the transformations of N and P in two different textured soils, namely clay loam and loamy sand, on mixing with rice straw biochar (RSB) and acacia wood biochar (ACB) at each level (0, 0.5, and 1.0% w/w). Ammonium N (NH4-N) decreased continuously with the increasing incubation period. The ammonium N content disappeared rapidly in both the soils incubated with biochars compared to the unamended soil. RSB increased the nitrate N (NO3-N) content significantly compared to ACB for the entire study period in both texturally divergent soils. The nitrate N content increased with the enhanced biochar addition rate in clay loam soil until 15 days after incubation; however, it was reduced for the biochar addition rate of 1% compared to 0.5% at 30 and 60 days after incubation in loamy sand soil. With ACB, the net increase in nitrate N content with the biochar addition rate of 1% remained higher than the 0.5% rate for 60 days in clay loam and 30 days in loamy sand soil. The phosphorus content remained consistently higher in both the soils amended with two types of biochars till the completion of the experiment.


Assuntos
Compostos de Amônio , Poluentes do Solo , Solo/química , Fósforo , Areia , Argila , Nitratos , Nitrogênio , Carvão Vegetal/química , Poluentes do Solo/análise
2.
Sci Rep ; 13(1): 6286, 2023 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-37072395

RESUMO

The quantum properties of fluorescent nanodiamonds offer great promise for fabricating quantum-enabled devices for physical applications. However, the nanodiamonds need to be suitably combined with a substrate to exploit their properties. Here, we show that ultrathin and flexible glass (thickness 30 microns) can be functionalized by nanodiamonds and nano-shaped using intense femtosecond pulses to design cantilever-based nanomechanical hybrid quantum sensors. Thus fabricated ultrathin glass cantilevers show stable optical, electronic, and magnetic properties of nitrogen-vacancy centers, including well-defined fluorescence with zero-phonon lines and optically detected magnetic resonance (ODMR) near 2.87 GHz. We demonstrate several sensing applications of the fluorescent ultrathin glass cantilever by measuring acoustic pulses, external magnetic field using Zeeman splitting of the NV centers, or CW laser-induced heating by measuring thermal shifting of ODMR lines. This work demonstrates the suitability of the femtosecond-processed fluorescent ultrathin glass as a new versatile substrate for multifunctional quantum devices.

3.
Sci Rep ; 12(1): 8525, 2022 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-35595769

RESUMO

We demonstrate a dispersion-free wavefront splitting attosecond resolved interferometric delay line for easy ultrafast metrology of broadband femtosecond pulses. Using a pair of knife-edge prisms, we symmetrically split and later recombine the two wavefronts with a few tens of attosecond resolution and stability and employ a single-pixel analysis of interference fringes with good contrast using a phone camera without any iris or nonlinear detector. Our all-reflective delay line is theoretically analyzed and experimentally validated by measuring 1st and 2nd order autocorrelations and the SHG-FROG trace of a NIR femtosecond pulse. Our setup is compact, offers attosecond stability with flexibility for independent beam-shaping of the two arms. Furthermore, we suggest that our compact and in-line setup can be employed for attosecond resolved pump-probe experiments of matter with few-cycle pulses.

4.
Opt Lett ; 45(18): 5266-5269, 2020 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-32932507

RESUMO

We introduce an ultra-thin attosecond optical delay line based on controlled wavefront division of a femtosecond infrared pulse after transmission through a pair of micrometer-thin glass plates with negligible dispersion effects. The time delay between the two pulses is controlled by rotating one of the glass plates from absolute zero to several optical cycles, with 2.5 as to tens of attosecond resolution with 2 as stability, as determined by interferometric self-calibration. The performance of the delay line is validated by observing attosecond-resolved oscillations in the yield of high harmonics induced by time delayed infrared pulses, in agreement with a numerical simulation for a simple model atom. This approach can be extended in the future for performing XUV-IR attosecond pump-probe experiments.

5.
Rev Sci Instrum ; 90(4): 043117, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31043051

RESUMO

We demonstrate a simple and versatile nanomechanical force measuring setup with 1 nN precision in air and vacuum using a load cell of an ultra-microbalance. We validate stability, precision, and linearity of the load cell with simple tests. The setup is customized to measure stress-strain response of biomaterials (silk, leaf, and flower) and capillary force in fluids. We isolated an optical pull force induced by a Watt-level laser reflected from a mirror/solid surface in air, in addition to optical push force. Furthermore, we add an interferometric probe to directly measure nanoscale deflection of cantilever of the load cell in real-time, thus bypassing its conventional electromagnetic readout, to improve speed and precision of the instrument. We demonstrate nanomechanical force measurement in high vacuum with the same precision and employ radiation pressure to calibrate the load cell for various precision measurements.

6.
Nat Mater ; 16(9): 938-945, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28805825

RESUMO

Spider silk is a tough, elastic and lightweight biomaterial, although there is a lack of tools available for non-invasive processing of silk structures. Here we show that nonlinear multiphoton interactions of silk with few-cycle femtosecond pulses allow the processing and heterostructuring of the material in ambient air. Two qualitatively different responses, bulging by multiphoton absorption and plasma-assisted ablation, are observed for low- and high-peak intensities, respectively. Plasma ablation allows us to make localized nanocuts, microrods, nanotips and periodic patterns with minimal damage while preserving molecular structure. The bulging regime facilitates confined bending and microwelding of silk with materials such as metal, glass and Kevlar with strengths comparable to pristine silk. Moreover, analysis of Raman bands of microwelded joints reveals that the polypeptide backbone remains intact while perturbing its weak hydrogen bonds. Using this approach, we fabricate silk-based functional topological microstructures, such as Mobiüs strips, chiral helices and silk-based sensors.

7.
Biomed Opt Express ; 6(12): 4694-704, 2015 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-26713187

RESUMO

In this work, we demonstrate that ultrafast laser irradiation could selectively disrupt vascular endothelium of zebrafish embryos in vivo. Ultrafast lasers minimize the collateral damage in the vicinity of the laser focus and eventually reduce coagulation in the tissues. We have also found that the threshold fluence for lesion formation of the vascular endothelium strongly depends on the developmental stage of the embryos. The threshold laser fluence required to induce apparent lesions in the vascular structure for Somite 14, 20 and 25 stages is about 5 J/cm(2) ~7 J/cm(2), which is much lower than that for the later development stages of Prim 16 and Prim 20 of 30 J/cm(2) ~50 J/cm(2). The proposed method for treating the vascular cord of zebrafish embryos in the early stage of development has potential as a selective and effective method to induce a fatal lesion in the vascular endothelium without damaging the developed blood vessels.

8.
Opt Express ; 23(15): 19854-62, 2015 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-26367645

RESUMO

We have investigated the effect of the dynamics of crater size on the poly(dimethylsiloxane) (PDMS) surface morphology in fs-laser micro-processing. PDMS surface was processed with varying both inter-pulse interval and inter-spot distance between successive laser pulses. With keeping the interval of 5 ms crater shape is round even if the spot is overlapped in space. But decreasing the interval to 0.02 ms the shape of the crater is no longer round. Decreasing the inter-distance between the craters results in roughened surface morphology even at time intervals of 5 ms. Temporal dependence of single-shot fs-laser induced crater size was measured as a function of time delay. Within 0.1 ms after pulse irradiation with a fluence of 4.8 J/cm2 on PDMS surface the crater size has reached to its maximum values and then decreased with a time constant of about 0.3 ms. The surface morphology after fs-laser pulse irradiation is strongly dependent on not only inter-spot distance between successive laser pulse but also their inter-pulse intervals. By proposing a theoretical model on their dynamic features, we will try to explain the current observation in quantitatively.

9.
Lasers Med Sci ; 29(4): 1417-27, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24570086

RESUMO

Nonlinear multiphoton absorption induced by focusing near infrared (NIR) femtosecond (fs) laser pulses into a transparent cornea allows surgery on neovascular structures with minimal collateral damage. In this report, we introduce an fs laser-based microsurgery for selective treatment of rat corneal neovascularizations (in vivo). Contiguous tissue effects are achieved by scanning a focused laser pulse below the corneal surface with a fluence range of 2.2-8.6 J/cm(2). The minimal visible laser lesion (MVL) threshold determined over the corneal neovascular structures was found to be 4.3 J/cm(2). Histological and optical coherence tomography examinations of the anterior segment after laser irradiations show localized degeneration of neovascular structures without any unexpected change in adjacent tissues. Furthermore, an approximately 30 % reduction in corneal neovascularizations was observed after 5 days of fs laser exposure. The femtosecond laser is thus a promising tool for minimally invasive intrastromal surgery with the aid of a significantly smaller and more deterministic photodisruptive energy threshold for the interaction between the fs laser pulse and corneal neovascular structures.


Assuntos
Córnea/irrigação sanguínea , Neovascularização da Córnea/cirurgia , Terapia a Laser/métodos , Lasers de Estado Sólido/uso terapêutico , Animais , Córnea/patologia , Córnea/cirurgia , Microcirurgia , Ratos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...